Pin | Name | Direction | Color | Description |
Z1 | GND | | | Ground |
Z2 | GND | | | Ground |
Z3 | GND | | | Ground |
Z4 | GND | | | Ground |
Z5 | GND | | | Ground |
Z6 | GND | | | Ground |
Z7 | GND | | | Ground |
Z8 | GND | | | Ground |
Z9 | GND | | | Ground |
Z10 | GND | | | Ground |
Z11 | GND | | | Ground |
Z12 | KEY | | | Keyed (no pin) |
Z13 | KEY | | | Keyed (no pin) |
Z14 | KEY | | | Keyed (no pin) |
Z15 | GND | | | Ground |
Z16 | GND | | | Ground |
Z17 | GND | | | Ground |
Z18 | GND | | | Ground |
Z19 | GND | | | Ground |
Z20 | GND | | | Ground |
Z21 | GND | | | Ground |
Z22 | GND | | | Ground |
Z23 | GND | | | Ground |
Z24 | GND | | | Ground |
Z25 | GND | | | Ground |
Z26 | GND | | | Ground |
Z27 | GND | | | Ground |
Z28 | GND | | | Ground |
Z29 | GND | | | Ground |
Z30 | GND | | | Ground |
Z31 | GND | | | Ground |
Z32 | GND | | | Ground |
Z33 | GND | | | Ground |
Z34 | GND | | | Ground |
Z35 | GND | | | Ground |
Z36 | GND | | | Ground |
Z37 | GND | | | Ground |
Z38 | GND | | | Ground |
Z39 | GND | | | Ground |
Z40 | GND | | | Ground |
Z41 | GND | | | Ground |
Z42 | GND | | | Ground |
Z43 | GND | | | Ground |
Z44 | GND | | | Ground |
Z45 | GND | | | Ground |
Z46 | GND | | | Ground |
Z47 | GND | | | Ground |
| | | | |
A1 | 5V | | | +5 VDC |
A2 | TCK | | | Test Clock |
A3 | INTA# | | | Interrupt A |
A4 | BRSV | | | Bused Reserved (don't use) |
A5 | BRSV | | | Bused Reserved (don't use) |
A6 | REQ# | | | Request PCI transfer |
A7 | AD(30) | | | Address/Data 30 |
A8 | AD(26) | | | Address/Data 26 |
A9 | C/BE(3)# | | | Command: Byte Enable |
A10 | AD(21) | | | Address/Data 21 |
A11 | AD(18) | | | Address/Data 18 |
A12 | KEY | | | Keyed (no pin) |
A13 | KEY | | | Keyed (no pin) |
A14 | KEY | | | Keyed (no pin) |
A15 | 3.3V | | | +3.3 VDC |
A16 | DEVSEL# | | | Device Select |
A17 | 3.3V | | | +3.3 VDC |
A18 | SERR# | | | System Error |
A19 | 3.3V | | | +3.3 VDC |
A20 | AD(12) | | | Address/Data 12 |
A21 | 3.3V | | | +3.3 VDC |
A22 | AD(7) | | | Address/Data 7) |
A23 | 3.3V | | | +3.3 VDC |
A24 | AD(1) | | | Address/Data 1) |
A25 | 5V | | | +5 VDC |
A26 | CLK1 | | | Clock ?? MHz |
A27 | CLK2 | | | Clock ?? MHz |
A28 | CLK4 | | | Clock ?? MHz |
A29 | V(I/O) | | | +3.3 VDC or +5 VDC |
A30 | C/BE(5)# | | | Command: Byte Enable |
A31 | AD(63) | | | Address/Data 63 |
A32 | AD(59) | | | Address/Data 59 |
A33 | AD(56) | | | Address/Data 56 |
A34 | AD(52) | | | Address/Data 52 |
A35 | AD(49) | | | Address/Data 49 |
A36 | AD(45) | | | Address/Data 45 |
A37 | AD(42) | | | Address/Data 42 |
A38 | AD(38) | | | Address/Data 38 |
A39 | AD(35) | | | Address/Data 35 |
A40 | BRSV | | | Bused Reserved (don't use) |
A41 | BRSV | | | Bused Reserved (don't use) |
A42 | BRSV | | | Bused Reserved (don't use) |
A43 | USR | | | User Defined |
A44 | USR | | | User Defined |
A45 | USR | | | User Defined |
A46 | USR | | | User Defined |
A47 | USR | | | User Defined |
| | | | |
B1 | -12V | | | -12 VDC |
B2 | 5V | | | +5 VDC |
B3 | INTB# | | | Interrupt B |
B4 | GND | | | Ground |
B5 | BRSV | | | Bused Reserved (don't use) |
B6 | GND | | | Ground |
B7 | AD(29) | | | Address/Data 29 |
B8 | GND | | | Ground |
B9 | IDSEL | | | Initialization Device Select |
B10 | GND | | | Ground |
B11 | AD(17) | | | Address/Data 17 |
B12 | KEY | | | Keyed (no pin) |
B13 | KEY | | | Keyed (no pin) |
B14 | KEY | | | Keyed (no pin) |
B15 | FRAME# | | | Address or Data phase |
B16 | GND | | | Ground |
B17 | SDONE | | | Snoop Done |
B18 | GND | | | Ground |
B19 | AD(15) | | | Address/Data 15 |
B20 | GND | | | Ground |
B21 | AD(9) | | | Address/Data 9) |
B22 | GND | | | Ground |
B23 | AD(4) | | | Address/Data 4) |
B24 | 5V | | | +5 VDC |
B25 | REQ64# | | | |
B26 | GND | | | Ground |
B27 | CLK3 | | | Clock ?? MHz |
B28 | GND | | | Ground |
B29 | BRSV | | | Bused Reserved (don't use) |
B30 | GND | | | Ground |
B31 | AD(62) | | | Address/Data 62 |
B32 | GND | | | Ground |
B33 | AD(55) | | | Address/Data 55 |
B34 | GND | | | Ground |
B35 | AD(48) | | | Address/Data 48 |
B36 | GND | | | Ground |
B37 | AD(41) | | | Address/Data 41 |
B38 | GND | | | Ground |
B39 | AD(34) | | | Address/Data 34 |
B40 | GND | | | Ground |
B41 | BRSV | | | Bused Reserved (don't use) |
B42 | GND | | | Ground |
B43 | USR | | | User Defined |
B44 | USR | | | User Defined |
B45 | USR | | | User Defined |
B46 | USR | | | User Defined |
B47 | USR | | | User Defined |
| | | | |
C1 | TRST# | | | Test Logic Reset |
C2 | TMS | | | Test Mode Select |
C3 | INTC# | | | Interrupt C |
C4 | V(I/O) | | | +3.3 VDC or +5 VDC |
C5 | RST | | | Reset |
C6 | 3.3V | | | +3.3 VDC |
C7 | AD(28) | | | Address/Data 28 |
C8 | V(I/O) | | | +3.3 VDC or +5 VDC |
C9 | AD(23) | | | Address/Data 23 |
C10 | 3.3V | | | +3.3 VDC |
C11 | AD(16) | | | Address/Data 16 |
C12 | KEY | | | Keyed (no pin) |
C13 | KEY | | | Keyed (no pin) |
C14 | KEY | | | Keyed (no pin) |
C15 | IRDY# | | | Initiator Ready |
C16 | V(I/O) | | | +3.3 VDC or +5 VDC |
C17 | SBO# | | | Snoop Backoff |
C18 | 3.3V | | | +3.3 VDC |
C19 | AD(14) | | | Address/Data 14 |
C20 | V(I/O) | | | +3.3 VDC or +5 VDC |
C21 | AD(8) | | | Address/Data 8) |
C22 | 3.3V | | | +3.3 VDC |
C23 | AD(3) | | | Address/Data 3) |
C24 | V(I/O) | | | +3.3 VDC or +5 VDC |
C25 | BRSV | | | Bused Reserved (don't use) |
C26 | REQ1# | | | Request PCI transfer |
C27 | SYSEN# | | | |
C28 | GNT3# | | | Grant |
C29 | C/BE(7) | | | Command: Byte Enable |
C30 | V(I/O) | | | +3.3 VDC or +5 VDC |
C31 | AD(61) | | | Address/Data 61 |
C32 | V(I/O) | | | +3.3 VDC or +5 VDC |
C33 | AD(54) | | | Address/Data 54 |
C34 | V(I/O) | | | +3.3 VDC or +5 VDC |
C35 | AD(47) | | | Address/Data 47 |
C36 | V(I/O) | | | +3.3 VDC or +5 VDC |
C37 | AD(40) | | | Address/Data 40 |
C38 | V(I/O) | | | +3.3 VDC or +5 VDC |
C39 | AD(33) | | | Address/Data 33 |
C40 | FAL# | | | Power Supply Status FAL (CompactPCI specific) |
C41 | DEG# | | | Power Supply Status DEG (CompactPCI specific) |
C42 | PRST# | | | Push Button Reset (CompactPCI specific) |
C43 | USR | | | User Defined |
C44 | USR | | | User Defined |
C45 | USR | | | User Defined |
C46 | USR | | | User Defined |
C47 | USR | | | User Defined |
| | | | |
D1 | +12V | | | +12 VDC |
D2 | TDO | | | Test Data Output |
D3 | 5V | | | +5 VDC |
D4 | INTP | | | |
D5 | GND | | | Ground |
D6 | CLK | | | |
D7 | GND | | | Ground |
D8 | AD(25) | | | Address/Data 25 |
D9 | GND | | | Ground |
D10 | AD(20) | | | Address/Data 20 |
D11 | GND | | | Ground |
D12 | KEY | | | Keyed (no pin) |
D13 | KEY | | | Keyed (no pin) |
D14 | KEY | | | Keyed (no pin) |
D15 | GND | | | Ground |
D16 | STOP# | | | Stop transfer cycle |
D17 | GND | | | Ground |
D18 | PAR | | | Parity for AD0-31 & C/BE0-3 |
D19 | GND | | | Ground |
D20 | AD(11) | | | Address/Data 11 |
D21 | M66EN | | | |
D22 | AD(6) | | | Address/Data 6) |
D23 | 5V | | | +5 VDC |
D24 | AD(0) | | | Address/Data 0) |
D25 | 3.3V | | | +3.3 VDC |
D26 | GNT1# | | | Grant |
D27 | GNT2# | | | Grant |
D28 | REQ4# | | | Request PCI transfer |
D29 | GND | | | Ground |
D30 | C/BE(4)# | | | Command: Byte Enable |
D31 | GND | | | Ground |
D32 | AD(58) | | | Address/Data 58 |
D33 | GND | | | Ground |
D34 | AD(51) | | | Address/Data 51 |
D35 | GND | | | Ground |
D36 | AD(44) | | | Address/Data 44 |
D37 | GND | | | Ground |
D38 | AD(37) | | | Address/Data 37 |
D39 | GND | | | Ground |
D40 | REQ5# | | | Request PCI transfer |
D41 | GND | | | Ground |
D42 | REQ6# | | | Request PCI transfer |
D43 | USR | | | User Defined |
D44 | USR | | | User Defined |
D45 | USR | | | User Defined |
D46 | USR | | | User Defined |
D47 | USR | | | User Defined |
| | | | |
E1 | 5V | | | +5 VDC |
E2 | TDI | | | Test Data Input |
E3 | INTD# | | | Interrupt D |
E4 | INTS | | | |
E5 | GNT# | | | Grant |
E6 | AD(31) | | | Address/Data 31 |
E7 | AD(27) | | | Address/Data 27 |
E8 | AD(24) | | | Address/Data 24 |
E9 | AD(22) | | | Address/Data 22 |
E10 | AD(19) | | | Address/Data 19 |
E11 | C/BE(2)# | | | Command: Byte Enable |
E12 | KEY | | | Keyed (no pin) |
E13 | KEY | | | Keyed (no pin) |
E14 | KEY | | | Keyed (no pin) |
E15 | TRDY# | | | Target Ready |
E16 | LOCK# | | | Lock resource |
E17 | PERR# | | | Parity Error |
E18 | C/BE(1)# | | | Command: Byte Enable |
E19 | AD(13) | | | Address/Data 13 |
E20 | AD(10) | | | Address/Data 10 |
E21 | C/BE(0)# | | | Command: Byte Enable |
E22 | AD(5) | | | Address/Data 5) |
E23 | AD(2) | | | Address/Data 2) |
E24 | ACK64# | | | |
E25 | 5V | | | +5 VDC |
E26 | REQ2# | | | Request PCI transfer |
E27 | REQ3# | | | Request PCI transfer |
E28 | GNT4# | | | Grant |
E29 | C/BE(6)# | | | Command: Byte Enable |
E30 | PAR64 | | | |
E31 | AD(60) | | | Address/Data 60 |
E32 | AD(57) | | | Address/Data 57 |
E33 | AD(53) | | | Address/Data 53 |
E34 | AD(50) | | | Address/Data 50 |
E35 | AD(46) | | | Address/Data 46 |
E36 | AD(43) | | | Address/Data 43 |
E37 | AD(39) | | | Address/Data 39 |
E38 | AD(36) | | | Address/Data 36 |
E39 | AD(32) | | | Address/Data 32 |
E40 | GNT5# | | | Grant |
E41 | BRSV | | | Bused Reserved (don't use) |
E42 | GNT6# | | | Grant |
E43 | USR | | | User Defined |
E44 | USR | | | User Defined |
E45 | USR | | | User Defined |
E46 | USR | | | User Defined |
E47 | USR | | | User Defined |
| | | | |
F1 | GND | | | Ground |
F2 | GND | | | Ground |
F3 | GND | | | Ground |
F4 | GND | | | Ground |
F5 | GND | | | Ground |
F6 | GND | | | Ground |
F7 | GND | | | Ground |
F8 | GND | | | Ground |
F9 | GND | | | Ground |
F10 | GND | | | Ground |
F11 | GND | | | Ground |
F12 | KEY | | | Keyed (no pin) |
F13 | KEY | | | Keyed (no pin) |
F14 | KEY | | | Keyed (no pin) |
F15 | GND | | | Ground |
F16 | GND | | | Ground |
F17 | GND | | | Ground |
F18 | GND | | | Ground |
F19 | GND | | | Ground |
F20 | GND | | | Ground |
F21 | GND | | | Ground |
F22 | GND | | | Ground |
F23 | GND | | | Ground |
F24 | GND | | | Ground |
F25 | GND | | | Ground |
F26 | GND | | | Ground |
F27 | GND | | | Ground |
F28 | GND | | | Ground |
F29 | GND | | | Ground |
F30 | GND | | | Ground |
F31 | GND | | | Ground |
F32 | GND | | | Ground |
F33 | GND | | | Ground |
F34 | GND | | | Ground |
F35 | GND | | | Ground |
F36 | GND | | | Ground |
F37 | GND | | | Ground |
F38 | GND | | | Ground |
F39 | GND | | | Ground |
F40 | GND | | | Ground |
F41 | GND | | | Ground |
F42 | GND | | | Ground |
F43 | GND | | | Ground |
F44 | GND | | | Ground |
F45 | GND | | | Ground |
F46 | GND | | | Ground |
F47 | GND | | | Ground |